分子生物学
IVD分子诊断
细胞培养与分析
蛋白研究
细胞因子
重组蛋白
抗体
高通量测序建库
病原检测UCF系列
生物医药
工具酶
抑制剂激活剂与常用试剂
仪器
耗材

124I-Labeled Monoclonal Antibody and Fragment for the Noninvasive Evaluation of Tumor PD-L1 Expression In Vivo

Yuan Cheng, Dai Shi, Zhan Xu, Zhihui Gao, Zhan Si, Yanzhao Zhao, Renjie Ye, Zhequan Fu, Wenhui Fu, Tingting Yang, Yan Xiu, Qingyu Lin, Dengfeng Cheng

Journal:MOLECULAR PHARMACEUTICS

IF:5.36

DOI:10.1021/acs.molpharmaceut.2c00084

PMID:35244407

Published:2022-03-04

research field:分子生物学病理生理学基因组学妇产科学

Abstract

Lung cancer is a highly heterogeneous cancer and is divided broadly into small and nonsmall cell lung cancer (SCLC or NSCLC). In all NSCLC patients, it is estimated that 50%–60% are programmed cell death ligand 1 (PD-L1) positive, and anti-PD-1/PD-L1 therapies have shown their clinical application prospects in advanced NSCLC. To avoid unnecessary adverse effects and provide anti-PD-1/PD-L1 therapy to the most appropriate patient population, the PD-L1 expression in patients preparing for treatment must be evaluated accurately and in real time. In this study, we noninvasively evaluate the PD-L1 expression in an NSCLC xenograft using 124I-labeled F(ab′)2 fragments of durvalumab (Durva) and compared it with the 124I-labeled intact antibody in terms of the biodistribution and dosimetry. The aim is to develop a nuclide labeled molecular probe with better performance for PD-L1 immunoPET imaging. After cleaving using IdeS protease, the F(ab′)2 fragments of Durva were labeled with 124I. The radioligand showed a high radiochemical purity (>96%) and outstanding stability. Western blot, quantitative real-time polymerase chain reaction, and flow cytometry were performed on the two selected NSCLC cell lines to measure the in vitro PD-L1 expression. The H460 cells showed a much higher PD-L1 expression than the A549 cells, both at the protein level and the mRNA level. In the following cell binding experiment and binding specificity assay, the labeled radioligand showed good affinity to high PD-L1 expression cells and could be blocked with excess unlabeled intact Durva. The results of the biodistribution and the positron emission tomography (PET) image showed that the peak tumor uptake of 124I-Durva-F(ab′)2 was close to 124I-Durva, but much earlier (5.29 ± 0.42% ID/g for 124I-Durva-F(ab′)2 at 12 h vs 5.18 ± 0.73% ID/g for 124I-Durva at 48 h). Compared with 124I-Durva, an accelerated blood clearance was observed for 124I-Durva-F(ab′)2. The faster blood clearance allowed for a higher

本文使用的Yeasen产品

购物车
客服
转染试用