A Mismatch-tolerant RT-LAMP Method for Molecular Diagnosis of Highly Variable Viruses

Yingxue Li, Yi Zhou, Yingying Ma, Rong Xu, Xia Jin, Chiyu Zhang

Journal:Bio-protocol

IF:0

DOI:10.21769/BioProtoc.3415

PMID:33654914

Published:2019-11-05

research field:医学诊断分子生物学病毒学

Abstract

Loop-mediated isothermal amplification (LAMP) has been widely used in the detection of pathogens. However, there are usually numerous variants in one viral pathogen and primers employed in LAMP can hardly match all these variants. The mismatches between the primers and the viral genomes, especially those at the 3′-end of the primers, hinder LAMP reactions, leading to failure of the detection. Here, we present a mismatch-tolerant RT-LAMP protocol, which utilizes the 3′-5′ exonuclease activity of the Q5 high-fidelity DNA polymerase to remove potential mismatched bases at the 3′-end of the primers during LAMP amplification. Using HIV-1 as a proof-of-principle, we showed that this protocol could represent a promising tool for accurate detection of genetically unstable viruses in laboratory, hospital and field.